webleads-tracker

Ultraprobe 15.000 IS - UE Systems

Ultraprobe 15.000 IS

Your Intrinsically Safe Solution For Total Plant Inspections.

15ISheading

 

Two Powerful Inspection Tools in One Package:

• The Ultraprobe® 15,000 Touch for advanced in-field diagnostics.
• The Ultraprobe® 9000ATEX to test in hazardous areas!

Total Plant Reliability

With the Ultraprobe 15,000 Plus IS Package you’ll be able to monitor equipment performance, improve asset availability and reduce energy waste throughout your plant… Including hazardous areas that require intrinsically safe ratings.

EX Access? No Problem! Now you can test anywhere

Divide routes into required and non-required EX rated inspection zones.

Use the Ultraprobe 9000ATEX as a screening tool to test the hazardous areas and the Ultraprobe 15,000 for the rest of the plant. By testing with the 9000ATEX in rated areas, anomalies can be identified early enough so that appropriate decisions can be made as to next steps or corrective actions.

The Ultraprobe® 15,000 Plus IS Package includes:

•  Ultraprobe 15,000 Touch Digital Pistol Unit

This advanced ultrasonic instrument can perform on-board spectral analysis, record the sounds of test equipment, measure and record temperature, take photographs with flash, store and manage data. The Ultraprobe 15,000 utilizes touch screen technology. This unique feature uses Icons to easily control and maneuver around any of the Ultraprobe’s display screens. Touching the screen allows you to be able to view decibel level, temperature, control sensitivity, change frequency, view an FFT and record sounds and images.

•  Ultraprobe 9000ATEX Digital Ultrasonic Inspection System

The Ultraprobe 9000 housing with Digital LCD Display and LED backlight FM Rated Intrinsically Safe: Class I, Division 1, Groups C & D.

• Tri-Sonic Scanning Module for locating airborne ultrasound (ATEX Rated)
• Stethoscope Module (contact type) for monitoring internally generated ultrasounds (ATEX Rated)
• Extension Probe Kit to increase stethoscope contact range to 31 inches
• Warble Tone Generator
• Deluxe Noise Isolating Headset for use with hardhat
• LRM Long Range Module to increase detection range
• Spectralyzer Sound Analysis Software / Ultratrend Data Management Software
• Rubber Focusing Probe for narrowing reception field & for shielding ambient ultrasounds
• 2 Battery Rechargers with Spare Battery & External Recharging POD for Ultraprobe 15,000 unit
• RAS-MT Magnetic Sensor with BNC connection readable with the Ram Module
• RAM Adaptor enabling the UP15,000 to read RAS sensors
• SD Card to USB Reader (allows reading of SD to PC via USB port)
• Zero Halliburton Case

SPECIFICATIONS OVERVIEW UP 15,000:

Construction: Hand-held pistol type made with coated aluminum and ABS plastic.
Circuitry: Solid State Analog and SMD Digital Circuitry with temperature compensation and true RMS conversion
Frequency Range: 20 kHz to 100 kHz (tunable in 1 kHz increments)
Response Time: < 10 ms
Display: QVGA Touch Screen – IR, Laser Pointer, Camera, Spectrum Ana
Sound Recording: WAV File Format
IR Temperature: -20 °C to 500 °C
Camera: 2.0 Mega Pixel
Laser Pointer: Europe Only OutputLaser Pointer:All but Europe Output
Memory: 400 storage locations
Battery: Lithium NiMH Rechargeable.
Operating Temperature: 0°C to 50°C (32 °F to 122 °F)
Output(s): Calibrated heterodyned output, decibel (dB), frequency, SD card
Probes: Trisonic Scanning Module and Stethoscope Module, Long Range Module and RAS-MT
Headset: Deluxe noise attentuating headphones for hard hat use
Indicators: dB,Frequency, Battery Status and 16 Segment Bar Graph.
Threshold: 1 x 10-2 std: cc/sec to 1 x 10-3 std. cc/sec
Dimensions: Complete kit in Zero Halliburton aluminium carrying case
55 x 47 x 20 cm (21.5″ x 18.5″ x 8″).
Weight: Pistol Unit: 1.1 kg (2,35 lbs)
Complete carrying case: 8.6 kg (19 lbs)
Warranty: 1 year parts/labor standard.
5 years with completed warranty registration card
Display Modes: dB (main), IR, ABCD, Spectrum and Application Specific, Spectrum Analyzer (modes): Spectrum, Time Series & Dual Specif
Ultraprobe 15,000 Kits: Meets and exceeds ASTM E1002-2005 requirements for Leak Detection
*depends on leak configuration

SPECIFICATIONS OVERVIEW UP 9000ATEX:

Construction: Hand-held pistol type made with coated aluminum and ABS plastic
Circuitry: Solid State SMD Digital Circuitry with temperature compensation
Frequency: 20 kHz to 100 kHz (tunable in 1 kHz increments)
Response time: <10 ms
Display: 16 x 2 LCD with LED Backlight
Memory: 400 storage locations
Battery: NiMH Rechargeable
Operating Temperature: 0 °C to 50 °C (32 °F to 122 °F)
Outputs: Calibrated heterodyned output, decibel (dB) frequency, USB data output
Probes: Trisonic Scanning Module and Stethoscope Module
Headset: Deluxe noise attenuating headphones for hard hat use
Indicators: dB, Frequency, Battery Status and 16 Segment Bar Graph
Sensitivity: Detects 0.127 mm (0.005”) diameter leak @ 0.34 bar (5 psi) at a distance of 15.24 m (50 ft.)
Threshold: 1 x 10–2 std. cc/sec to 1 x 10–3 std. cc/sec
Dimensions: Complete kit in Zero Halliburton aluminum carrying case
47 x 37 x 17 cm (18.5” x 14.5” x 6.5”)
Pistol Unit: 0.9 kg (2 lbs.)
Complete carrying case: 6.4 kg (14 lbs.)
Weight: 1 kg (2 lbs.)
Warranty: 1-year parts/labor standard, 5 years with completed warranty registration card.
Display Modes: Real Time, Snap Shot, Peak Hold and Storage Display*depends on leak configuration
**specify Ex rating if needed at time of order

Brochure UP 15000 IS

Brochure UP 15000

Brochure UP 9000ATEX

Brochure UP Accessories

Brochure UP Applications

Manual UP 15000

Manual UP 9000ATEX

Manual Spectralyser 4 Software

Manual DMS 5 Software

DHC-2HH-BT manual placeholder

Manual DHC-2HH Bluetooth Headset

 

View online tutorials & webinars in our learning center section >


  • DHC-2BT: DELUXE BLUETOOTH HEADSET FOR USE WITH HARDHAT

    Wireless Bluetooth headset for use in high noise environments. Acts as hearing protection device. Convenient for use with hard hats. Velcro loop head band adjusts for all sizes.


  • CFM-15: CLOSE FOCUS MODULE

    A specialized module to help locate LOW LEVEL pressure and vacuum leaks.

 

Download a copy of the UP15,000 CE declaration of conformity >

 

Ultraprobe 15,000 is covered by one or more of the following patents:
0151115; 0303776; 0315199; 1206586; 1297576; 1881263; 2562758; 2689339; 4416145; 4823600; 5955670; 6122966; 6339961; 6341518; 6415645; 6655214; 6707762; 6804992

Ultraprobe 15,000 meets and exceeds ASTM E1002-2005 requirements for leak detection.

 

Download a copy of the UP9000 CE declaration of conformity >

 

Ultraprobe 9000 is covered by one or more of the following patents:
0151115; 0303776; 0315199; 1206586; 1297576; 1881263; 2562758; 2689339; 4416145; 4823600; 5955670; 6122966; 6339961; 6341518; 6415645; 6655214; 6707762; 6804992

Ultraprobe 9000 meets and exceeds ASTM E1002-2005 requirements for leak detection.